35

Functional check
• No suspicious noises
• Starter fully functional
• Engine switch fully functional
• Test for maximum load

(Recommendation: use the LUKAS test kit, including testing instructions, for the functional
check).

10.3 Hydraulic units with electric motor

Visual inspection

Hydraulic units
• All hydraulic connections are tightened
• General tightness, no leakage (sweated oils do not have any in

À uence on the function)

• Obvious damage to the motor/engine, valve blocks or casing
• Side panels present and securely

¿ tted

• Type plate, all activation plates, signs, identi

¿ cation marks and warning labels are present

and legible

• All covers (e.g. fan cover) are present and undamaged
• Liquid levels are within the speci

¿ ed tolerances

• ON/OFF switch in proper working order, undamaged
• Couplings must be easy to couple
• Dust protection caps must be available
• All electrical attachments (such as cables and plugs) must be present and undamaged
• Toolholder (if available) is undamaged and fully functional
• Carrying handles (if available) are undamaged and fully functional

Functional check
• No suspicious noises
• Test for maximum load

(Recommendation: use the LUKAS test kit, including testing instructions, for the functional
check).