Trouble

Check

Cause

Solution

The motor / engine
is running, but
the connected
rescue equipment
does not move
when the valve is
actuated.

Check hose line

Hose line not
connected properly or
is damaged

Inspect the connection
of the hose line and,
if necessary, reconnect

Check the
position of the
valve lever on the
pump block of the
hydraulic unit

Valve not switched to
pressurise the supply
line.

Switch valve to
pressurise the supply
line.

Defective pump unit

Have repaired by
authorised dealer or
directly by LUKAS

Connect another
device and
check whether it
functions when
the valve is
actuated

The previously
connected device is
defective.

For the solution,
consult the operating
instructions for the
connected device

Mono-coupling
(female) defective

Replace mono-coupling
(female)

The connected
rescue equipment
does not move on
activation of the
valve, or moves
only very slowly or
unevenly.

Connect another
device and
check whether it
functions when
the valve is
actuated

The previously
connected device is
defective.

For the solution,
consult the operating
instructions for the
connected device

Check the
position of the
valve lever on the
pump block of the
hydraulic unit

Pressure relief on
the unit is still active
(circulation at static
pressure)

Check the switching
positions of the
valve lever(s) and,
if necessary, reset
(as far as the

¿ nal

position)

Defective pump unit

Have repaired by
authorised dealer or
directly by LUKAS

Air in hydraulic system Vent the hydraulic

system

Mono-coupling
(female) defective

Replace mono-coupling
(female)