SECTION 5 - HYDRAULICS

3121284

– JLG Lift –

5-43

Control Solenoids

REMOVAL

1.

Disconnect electrical connection and remove the three
cap screws (D050) using a 4 mm internal hex wrench.

2.

Remove the solenoid (D025) and O-ring (D025A). Dis-
card the O-ring.

3.

If necessary, remove the coil using a 12 point 26 mm
socket.

INSPECTION

1.

Inspect the machined surface on the control. If you find
any nicks or scratches, replace the component.

REASSEMBLY

1.

Lubricate new O-ring (D025A) using petroleum jelly and
install.

2.

Install solenoid with three cap screws (D050) using a 4
mm internal hex wrench. Torque screws to 5 N•m [4
lbf•ft].

3.

Install coil using a 12 point 26 mm socket. Torque coil
nut to 5 N•m [3.7 lbf•ft].

4.

Reconnect electrical connections and test the pump for
proper operation.

Figure 5-47. Control Module Removal/Installation