SECTION 7 - BASIC ELECTRICAL INFORMATION & SCHEMATICS

7-6

– JLG Lift –

3121284

AMP JUNIOR TIMER

This type of connector uses back-seals for moisture integrity.
However, the low-force contacts cannot displace dielectric
grease and create electrical contact. It is possible to use sol-
vents (i.e. contact cleaner or mineral spirits) for the removal of
improperly applied dielectric grease. The EMR2 engine control
module from Deutz employs this connector system (for exam-
ple).

SEALED ENCLOSURES

Application of dielectric grease is not required in properly
sealed enclosures. To meet criteria, the enclosure must be
rated to at least IP66 (dust tight; protected from powerful jets
of water). The enclosure must be fitted with a high quality,
continuous gasket and all wiring must pass through cable
entrances.

MIL-C-5015 SPEC CONNECTORS

Crown Connector Inc's recommendation is to not use dielec-
tric grease for this series connector. For similar model series
connectors, the manufacturer should be contacted for confir-
mation before applying dielectric grease. A typical application
for this connector is on David Clark Intercom connections in
Aerial Work Platforms.