SECTION 6 - JLG CONTROL SYSTEM

3121284

– JLG Lift –

6-37

FUNCTION PROBLEM - LIFT UP
PERMANENTLY SELECTED

23107

The machine is in Ground mode and the Lift switch is selected and
trying to activate the Lift Up function at startup.

Lift Up and Down prohibited.

With the machine controls not
enabled, return the Lift switch
to neutral. Actuate switch
while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace the switch if defective.

FUNCTION PROBLEM - LIFT
DOWN PERMANENTLY
SELECTED

23108

The machine is in Ground mode and the Lift switch is selected and
trying to activate the Lift Down function at startup.

Lift Up and Down prohibited.

With the machine controls not
enabled, return the Lift switch
to neutral. Actuate switch
while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace the switch if defective.

FUNCTION PROBLEM - TELE-
SCOPE IN PERMANENTLY
SELECTED

23109

The machine is in Ground mode and the Telescope switch is selected
and trying to activate the Telescope In function at startup.

Tele In and Out prohibited.

With the machine controls not
enabled, return the Lift switch
to neutral. Actuate switch
while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace the switch if defective.

FUNCTION PROBLEM - TELE-
SCOPE OUT PERMANENTLY
SELECTED

23110

The machine is in Ground mode and the Telescope switch is selected
and trying to activate the Telescope Out function at startup.

Tele In and Out prohibited.

With the machine controls not
enabled, return the Lift switch
to neutral. Actuate switch
while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace the switch if defective.

FUNCTION PROBLEM - PLAT-
FORM LEVEL UP PERMA-
NENTLY SELECTED

23111

The machine is in Ground mode and the Platform Level switch is
selected and trying to activate the Platform Level Up function at
startup.

Platform Level Up and Down
prohibited.

With the machine controls not
enabled, return the Lift switch
to neutral. Actuate switch
while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace the switch if defective.

FUNCTION PROBLEM - PLAT-
FORM LEVEL DOWN PERMA-
NENTLY SELECTED

23112

The machine is in Ground mode and the Platform Level switch is
selected and trying to activate the Platform Level Down function at
startup.

Platform Level Up and Down
prohibited.

With the machine controls not
enabled, return the Lift switch
to neutral. Actuate switch
while monitoring state
changes under appropriate
menu in DIAGNOSTICS-->OPER
CONTROLS on Analyzer.
Replace the switch if defective.

Table 6-5. Fault Code Troubleshooting Information

Help Message

DTC

Condition Producing DTC

Control System Response or

Machine Condition

Corrective Action/

Operational Requirement

for Function Movement

and/or to Clear Fault