SECTION 6 - JLG CONTROL SYSTEM

6-48

– JLG Lift –

3121284

PLATFORM ROTATE LEFT
VALVE – SHORT TO GROUND

3411

The Platform Module detects a short to ground at the Platform
Rotate Left Valve output and reports it to the Ground Module.

Platform Rotate Right and Left
outputs are disabled.

Inspect wiring for physical
damage and check for wire
continuity. Check for coil dam-
age or shorting condition in
connector. Cycle power to clear
the fault.

PLATFORM ROTATE RIGHT
VALVE – OPEN CIRCUIT

3412

The Platform Module detects an open circuit at the Platform Rotate
Right Valve output and reports it to the Ground Module.

Platform Rotate speed is lim-
ited to Creep

Check for a good connection at
the solenoid and for continuity
through this circuit. Inspect
wiring for physical damage.
Cycle power to clear the fault.

PLATFORM ROTATE RIGHT
VALVE – SHORT TO BATTERY

3413

The Platform Module detects a short to battery at the Platform
Rotate Right Valve output and reports it to the Ground Module.

Platform Rotate Right, Rotate
Left, and Flow Control Valve
outputs.

Inspect wiring for physical
damage and check for wire
continuity. Cycle power to clear
the fault.

PLATFORM ROTATE RIGHT
VALVE – SHORT TO GROUND

3414

The Platform Module detects a short to ground at the Platform
Rotate Right Valve output and reports it to the Ground Module.

Platform Rotate Right and Left
outputs are disabled.

Inspect wiring for physical
damage and check for wire
continuity. Check for coil dam-
age or shorting condition in
connector. Cycle power to clear
the fault.

JIB LIFT UP VALVE – OPEN CIR-
CUIT

3415

The Platform Module detects an open circuit at the Jib Lift Up Valve
output and reports it to the Ground Module.

Jib Lift speed is limited to Creep.

Check for a good connection at
the solenoid and for continuity
through this circuit. Inspect
wiring for physical damage.
Cycle power to clear the fault.

JIB LIFT UP VALVE – SHORT TO
BATTERY

3416

The Platform Module detects a short to battery at the Jib Lift Up Valve
output and reports it to the Ground Module.

Jib Lift Up and Flow Control
Valve outputs are disabled; Jib
Lift Down speed is limited to
Creep

Check for a good connection at
the solenoid and for continuity
through this circuit. Inspect
wiring for physical damage.
Cycle power to clear the fault.

JIB LIFT UP VALVE – SHORT TO
GROUND

3417

The Platform Module detects a short to ground at the Jib Lift Up Valve
output and reports it to the Ground Module.

Jib Lift Up output is disabled;
Jib Lift Down speed is limited to
Creep

Inspect wiring for physical
damage and check for wire
continuity. Check for coil dam-
age or shorting condition in
connector. Cycle power to clear
the fault.

JIB LIFT DOWN VALVE – OPEN
CIRCUIT

3418

The Platform Module detects an open circuit at the Jib Lift Down
Valve output and reports it to the Ground Module.

Jib Lift speed is limited to Creep.

Check for a good connection at
the solenoid and for continuity
through this circuit. Inspect
wiring for physical damage.
Cycle power to clear the fault.

Table 6-5. Fault Code Troubleshooting Information

Help Message

DTC

Condition Producing DTC

Control System Response or

Machine Condition

Corrective Action/

Operational Requirement

for Function Movement

and/or to Clear Fault