JLG 18RS Service Manual User Manual

Page 18

Advertising
background image

SECTION 1 - SPECIFICATIONS

1-6

– JLG Lift –

3121284

2. Swing Bearing/Worm Gear Teeth

Lube Point(s) - Grease Fitting
Capacity - A/R
Lube - Lubriplate 930-AAA
Interval - A/R

Lube Point(s) - Grease Fitting*
Capacity - A/R
Lube - Mobile SHC 007
Interval - A/R

DO NOT OVERGREASE BEARINGS. OVERGREASING BEARINGS
WILL RESULT IN DAMAGE TO OUTER SEAL IN HOUSING.

*If necessary install grease fitting into worm gear
housing and grease. Replace fitting with pipe plug
when complete.

3. Hydraulic Tank

Lube Point(s) - Fill Cap
Capacity - 36 Gal. (136.3 L), 32.5 Gal. (123 L) to Full

Level; 26.5 Gal (100.3 L) to Refill Mark

Lube - HO
Interval - Check Level daily; Change every 2 years or

1200 hours of operation.

Comments - On new machines, those recently over-

hauled, or after changing hydraulic oil, operate all
systems a minimum of two complete cycles and
recheck oil level in reservoir.

4. Hydraulic Tank Return Filter and Breather

Interval - Change after first 50 hrs. and every 6

months or 300 hrs. thereafter.

Comments - For breather element, remove wing nut

and cover to replace. Under certain conditions, it
may be necessary to replace both elements on a
more frequent basis.

Advertising