SECTION 6 - JLG CONTROL SYSTEM

3121284

– JLG Lift –

6-43

SWING LEFT VALVE – SHORT
TO GROUND

33122

The Ground Module detects a short to ground at the Swing Left Valve
output.

Ground Module Swing Left and
Right outputs are disabled.

Inspect wiring for physical
damage and check for wire
continuity. Check for coil dam-
age or shorting condition in
connector. Cycle power to clear
the fault.

TELESCOPE OUT VALVE –
SHORT TO BATTERY

33123

The Ground Module detects a short to battery at the Telescope Out
Valve output.

Ground Module Telescope In,
Telescope Out, and Flow Con-
trol Valve outputs are disabled.

Inspect wiring for physical
damage and check for wire
continuity. Cycle power to clear
the fault.

LIFT VALVES – SHORT TO BAT-
TERY

33182

The Ground Module detects a short to battery at either the Lift Up or
Lift Down valve

The Ground Module Lift Up and
Down outputs are disabled and
ground current return path is
open circuited.

Inspect wiring for physical
damage and check for wire
continuity. Cycle power to clear
the fault.

TELESCOPE OUT VALVE –
OPEN CIRCUIT

33186

The Ground Module detects an open circuit at the Telescope Out Valve
output.

Tele speed is limited to Creep

Check for a good connection at
the solenoid and for continuity
through this circuit. With the
solenoid disconnected, an
open circuit voltage of nearly
8.0V exists on the Ground Mod-
ule output pin for diagnostic
purposes. Inspect wiring for
physical damage. Cycle power
to clear the fault.

TELESCOPE OUT VALVE –
SHORT TO GROUND

33188

The Ground Module detects a short to ground at the Telescope Out
Valve output.

Ground Module Telescope Out
output is disabled; Tele In
speed is limited to Creep.

Inspect wiring for physical
damage and check for wire
continuity. Check for coil dam-
age or shorting condition in
connector. Cycle power to clear
the fault.

TELESCOPE IN VALVE – OPEN
CIRCUIT

33189

The Ground Module detects an open circuit at the Telescope In Valve
output.

Tele speed is limited to Creep

Check for a good connection at
the solenoid and for continuity
through this circuit. With the
solenoid disconnected, an
open circuit voltage of nearly
8.0V exists on the Ground Mod-
ule output pin for diagnostic
purposes. Inspect wiring for
physical damage. Cycle power
to clear the fault.

TELESCOPE IN VALVE – SHORT
TO GROUND

33190

The Ground Module detects a short to ground at the Telescope In
Valve output.

Ground Module Telescope In
and Out outputs are disabled.

Inspect wiring for physical
damage and check for wire
continuity. Check for coil dam-
age or shorting condition in
connector. Cycle power to clear
the fault.

Table 6-5. Fault Code Troubleshooting Information

Help Message

DTC

Condition Producing DTC

Control System Response or

Machine Condition

Corrective Action/

Operational Requirement

for Function Movement

and/or to Clear Fault