SECTION 3 - CHASSIS & TURNTABLE

3121284

– JLG Lift –

3-41

Glow Plugs

The diesel engine has glow plugs, controlled by the ground
module to assist in cold starting.

The Ground Module calculates the length of time the glow
plugs are energized prior to startup based upon ambient tem-
perature, engine coolant temperature, and battery voltage.
Refer to Table 3-5, Glow Plug Conditions.

The glow plugs are deenergized if:

• The Engine State is Engine Cranking, Engine Starting,

Engine running

or

• The Emergency Descent Mode is activated and Lift Down,

Tower Lift Down, or Jib Lift Down are active.

If the STARTER LOCKOUT option is enabled in the Machine
Setup, the Ground Module will not allow an engine start
attempt until the glow plug time has expired. If this option is
not enabled, the glow plug time can be interrupted and an
engine start attempt can be made. Starter Lockout is only
applicable for the first glow plug cycle.

Ambient Air Temperature Sensor

The ambient air temperature sensor is integrated within the
Ground Module. The sensor provides temperature information
the engine control system uses to set its fuel, spark, and air set-
tings for engine starting in cold environments.

3.15 COUNTERWEIGHT

If the counterweight has been removed, ensure the retaining
bolts are torqued to the proper value as shown in Figure 3-14.,
Counterweight Bolt Torque.

NOTE:

The left counterweight weighs approximately 937.6 ± 30.8
lbs. (425.3 ± 14 kg) and the right counterweight weighs
approximately 937.2 ± 30.8 lbs. (425.1 ±14 kg). Actual
weight is stamped on the counterweight.

Table 3-5. Glow Plug Conditions

Engine Coolant

Temperature

Battery
Voltage

Ambient

Temperature

Glow Plug

Time On

Greater than or

equal to

122 º F (50 º C)

- -

- -

Off

- -

Less than 11V

- -

Off

Less than

122 º F (50 º C)

Greater than

11V

Greater than

59ºF(15ºC)

Off

Less than

122 º F (50 º C)

Greater than

11V

Temp Between

23ºF and 59ºF

(-5ºC and 15ºC)

On for

10 sec.

Less than

122 º F (50 º C)

Greater than

11V

Temp Between

5ºF and 23ºF

(-15ºC and -5ºC)

On for

15 sec.

Less than

122 º F (50 º C)

Greater than

11V

Temp Less

Than

5ºF (-15ºC)

On for

20 sec.