SECTION 1 - SPECIFICATIONS

1-4

– JLG Lift –

3121284

Table 1-9. Function Speeds

Function

Adjustment

Ranges

Default
Setting

Time

Range

In Seconds

DRIVE

Max Speed

Accel

25 – 2000mA/s

275 mA/s

Decel

25 – 2000mA/s

175 mA/s

Min

250 – 1800mA

635 mA

Max

250 – 1800mA

1650 mA

52-58

ME/ MT

Accel

25 – 2000mA/s

300 mA/s

ME/ MT

Decel

25 – 2000mA/s

100 mA/s

Drive to Stop

Decel

25 – 2000mA/s

1075 mA/s

ME/ MT:

Min

250 – 1800mA

625 mA

Max Torque

Max

250 – 1800mA

1650 mA

Mid Engine

Max

250 – 1800mA

1650 mA

MT: Elevated

Max

250 – 1400mA

1125 mA

44 - 57

ME: Elevated

Max

250 – 1400mA

1200 mA

Max Torque

Creep

250 – 1400mA

1125 mA

Mid Engine

Creep

250 – 1400mA

1200 mA

ME = Max Engine, MT = Max Touque

SWING

Accel

0-5s

2.5 s

Decel

0-5s

1 s

LEFT

Min

250 – 1400mA

635 mA

Max

250 – 1400mA

1000 mA

80 - 100

Creep

250 – 1400mA

775 mA

RIGHT

Min

250 – 1400mA

635 mA

Max

250 – 1400mA

900 mA

80 - 100

Creep

250 – 1400mA

735 mA

LIFT

Accel

0-5s

2 s

Decel

0-5s

1 s

UP

Min

250 – 1400mA

400 mA

Max

250 – 1400mA

825 mA

46 - 59

Creep

250 – 1400mA

600 mA

DOWN

Min

250 – 1400mA

400 mA

Max

250 – 1400mA

1025 mA

39 - 51

Creep

250 – 1400mA

600 mA

TELECOPE

Accel

0-5s

2 s

Decel

0-5s

0.3 s

IN

Min

250 – 1400mA

625 mA

Max

250 – 1400mA

1200 mA

44 - 55

Creep

250 – 1400mA

790 mA

OUT

Min

250 – 1400mA

450 mA

Max

250 – 1400mA

1200 mA

41 - 51

Creep

250 – 1400mA

675 mA

PLATFORM ROTATE

LEFT

Max

No Adjustment

N/A

24 - 30

RIGHT

Max

No Adjustment

N/A

24 - 30

GROUND MODE

SWING

Left

250 – 1400mA

865 mA

N/A

Right

250 – 1400mA

765 mA

N/A

LIFT

Up

250 – 1400mA

725 mA

N/A

Down

250 – 1400mA

750 mA

N/A

TELESCOPE

In/Out

250 – 1400mA

1200 mA

N/A

1001147535-C

Table 1-9. Function Speeds

Function

Adjustment

Ranges

Default
Setting

Time

Range

In Seconds

Advertising