Lubricating oil for reduction gears, Lubricating oil for reduction gears -19 – JLG 600SC_660SJC Service Manual User Manual

Page 111

Advertising
background image

SECTION 5 - CAT CHASSIS (S/N 0300128000 TO PRESENT)

3121157

– JLG Lift –

5-19

Lubricating Oil for Reduction Gears

1.

Inspection of Contaminated Lubricating Oil

Check for metal powder or any other foreign sub-
stances deposited in the fluid at the time of oil
change.

2.

Frequencies of Oil Change

Gauging Procedure

Motor with the lubricating port on base-plate.

Remove socket head bolt for lubricating port (50) on the
base-plate (32) and plug for gauging port, and make sure
that lubricant flows out of the oil level detection port (45).
(Refer Figure 5-19.)

Motor with/without the lubricating port on base-plate.

Remove plug for lubricating port (1-8) on the cover (1-27)
and plug for gauging port, and make sure that lubricant
flows out of the oil level detection port (1-8). (Refer Figure
5-19.)

New lubricant replacement procedure

Motor with the lubricating port on base-plate.

Discharge old lubricant completely by removing socket
head bolts for lubricating port (50) and discharge port on
the base-plate (32) and plug for gauging port (45). Then,
lubricate new lubricant until lubricant flows out of the
gauging port. (Refer Figure 5-19.)

Motor with/without the lubricating port on base-plate.

Discharge old lubricant completely by removing plugs for
lubricating port (1-8) and discharge port on the cover (1-
27) and plug for gauging port (1-8).

Then, lubricate new lubricant until lubricant flows out of
the gauging port.(Refer Figure 5-19.)

Initial Oil Change

100 - 250 hrs

Succeeding Oil Change

every 1000 - 1500 hrs

Advertising