Troubleshooting for low pressure shuttle valve, Troubleshooting for low pressure shuttle valve -23 – JLG 600SC_660SJC Service Manual User Manual

Page 115

Advertising
background image

SECTION 5 - CAT CHASSIS (S/N 0300128000 TO PRESENT)

3121157

– JLG Lift –

5-23

Troubleshooting for Low Pressure Shuttle Valve

TROUBLES (TYPE OF FAILURE)

POSSIBLE CAUSES

CORRECTIVE ACTIONS

Motor rotates slowly.

Operation failure of plunger;
1) Foreign substances are jammed between plunger
and body.
2) Spring is broken.

- Remove foreign articles thoroughly. Repair dam-
aged parts, and reassemble the parts after cleanup. If
deep scratches or more than normal wear are found
on the parts, the parts should be replaced with new
ones.
- Replace spring with new one.

Motor does not stop or stops slowly.

Plunger does not return;
1) Foreign substances are jammed.
2) Spring is broken.
3) Spring is not assembled.

- Remove foreign articles thoroughly. Repair dam-
aged parts, and reassemble the parts after cleanup. If
deep scratches or more than normal wear are found
on the parts, the parts should be replaced with new
ones.
- Replace spring with new one.
- Install spring in proper position.

Rise in oil temperature of circuit

Operation failure of plunger
1) Foreign substances are jammed.
2) Orifice is clogged.

- Remove foreign articles thoroughly. Repair dam-
aged parts, and reassemble the parts after cleanup. If
deep scratches or more than normal wear are found
on the parts, the parts should be replaced with new
ones.
- Wash the orifice before reassembly.