JLG 600SC_660SJC Service Manual User Manual
Page 24
SECTION 1 - SPECIFICATIONS
1-6
– JLG Lift –
3121157
2.
Swing Drive Hub
Lube Point(s) - Level/Fill Plug
Capacity - 17 oz. (1/2 Full)
Lube - EPGL
Interval - Check level every 3 months or 150 hrs of
operation; change every 2 years or 1200 hours of
operation
3.
Final Drive Hub
Lube Point(s) - Level/Fill Plug
Capacity - 2.1 gal.(7.9 L); 1/2 Full
Lube - EPGL
Interval - Check level every 3 months or 150 hrs of
operation; change every 2 years or 1200 hours of
operation
4.
Hydraulic Return Filter
Interval - Change after first 50 hrs. and every 6
months or 300 hrs. thereafter or as indicated by
Condition Indicator.
5.
Hydraulic Charge Filter
Interval - Change after first 50 hrs. and every 6
months or 300 hrs. thereafter or as indicated by
Condition Indicator.
6.
Hydraulic Tank
Lube Point(s) - Fill Cap
Capacity - 30.6 gal. Tank; 32.7 gal. System
Lube - HO
Interval - Check Level daily; Change every 2 years or
1200 hours of operation.