JLG 600SC_660SJC Service Manual User Manual
Page 322
SECTION 9 - JLG CONTROL SYSTEM
9-26
– JLG Lift –
3121157
BASKET ROTATE
Acceleration
0.1 to 5.0 sec
1.8
Deceleration
0.1 to 3.0 sec
0.7
Mlnimum Left Speed
0 to 65%
42
Maximum Left Speed
0 to 100%
50
Minimum Right Speed
0 to 65%
42
Maximum Right Speed
0 to 100%
50
Engine RPM
800 to 2900
1800
JIB LIFT
Acceleration
0.1 to 5.0 sec
5.0
Deceleration
0.1 to 3.0 sec
1.0
Minimum Up Speed
0 to 65%
46
Maximum Up Speed
0 to 100%
54
Minimum Down Speed
0 to 65%
46
Maximum Down Speed
0 to 100%
54
Engine RPM
800 to 2900
1800
STEER
MAXimum speed
0 to 100%
N/A
Engine RPM
800 to 2900
N/A
GROUND MODE
Tower Lift Up Speed
0 to 100%
N/A
Tower Lift Down Speed
0 to 100%
N/A
Upper Lift Up
0 to 100%
60
Upper Lift Down
0 to 100%
60
Swing Speed
0 to 100%
60
Upper Telescope Speed
0 to 100%
70
Tower Telescope Speed
0 to 100%
N/A
Basket Rotate Speed
0 to 100%
50
Basket Level Speed
0 to 100%
50
Jib Lift Speed
0 to 100%
50
Jib Swing
0 to 100%
N/A
NOTE:
Personality settings can be adjusted anywhere within the adjustment range in order to achieve optimum machine performance.
4150365-6
Table 9-1. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS - 600SC