SECTION 9 - JLG CONTROL SYSTEM

9-26

– JLG Lift –

3121157

BASKET ROTATE

Acceleration

0.1 to 5.0 sec

1.8

Deceleration

0.1 to 3.0 sec

0.7

Mlnimum Left Speed

0 to 65%

42

Maximum Left Speed

0 to 100%

50

Minimum Right Speed

0 to 65%

42

Maximum Right Speed

0 to 100%

50

Engine RPM

800 to 2900

1800

JIB LIFT

Acceleration

0.1 to 5.0 sec

5.0

Deceleration

0.1 to 3.0 sec

1.0

Minimum Up Speed

0 to 65%

46

Maximum Up Speed

0 to 100%

54

Minimum Down Speed

0 to 65%

46

Maximum Down Speed

0 to 100%

54

Engine RPM

800 to 2900

1800

STEER

MAXimum speed

0 to 100%

N/A

Engine RPM

800 to 2900

N/A

GROUND MODE

Tower Lift Up Speed

0 to 100%

N/A

Tower Lift Down Speed

0 to 100%

N/A

Upper Lift Up

0 to 100%

60

Upper Lift Down

0 to 100%

60

Swing Speed

0 to 100%

60

Upper Telescope Speed

0 to 100%

70

Tower Telescope Speed

0 to 100%

N/A

Basket Rotate Speed

0 to 100%

50

Basket Level Speed

0 to 100%

50

Jib Lift Speed

0 to 100%

50

Jib Swing

0 to 100%

N/A

NOTE:

Personality settings can be adjusted anywhere within the adjustment range in order to achieve optimum machine performance.

4150365-6

Table 9-1. Personality Ranges/Defaults