background image

SECTION 9 - JLG CONTROL SYSTEM

9-24

– JLG Lift –

3121157

RIGHT TRACK

Accel

0.1 to 5.0 sec

2.0

Decel

0.1 to 3.0 sec

0.7

For. Min.

0 to 100%

12

For. Max.

0 to 100%

36

Rev. Min.

0 to 100%

19

Rev. Max.

0 to 100%

45

Elevated Fwd. Max.

0 to 100%

29

Elevated Rev. Max.

0 to 100%

35

Creep Fwd. Max

0 to 100%

19

Creep Rev. Max

0 to 100%

28

Engine RPM

1200 to 1600

1800

TOWER LIFT

Accel

0.1 to 5.0 sec

N/A

Decel

0.1 to 3.0 sec

N/A

Mlnimum Up Speed

0 to 60%

N/A

Maximum Up Speed

0 to 100%

N/A

Minimum Down Speed

0 to 60%

N/A

Maximum Down Speed

0 to 100%

N/A

Engine RPM

800 to 2900

N/A

UPPER LIFT

Accel

0.1 to 5.0 sec

2.0

Decel

0.1 to 3.0 sec

0.7

Mlnimum Up Speed

0 to 60%

40

Maximum Up Speed

0 to 100%

66

Creep Maximum Up Speed

0 to 65%

55

Minimum Down Speed

0 to 60%

40

Maximum Down Speed

0 to 100%

85

Creep Maximum Down Speed

0 to 75%

55

Engine RPM

800 to 2900

1800

Table 9-1. Personality Ranges/Defaults