SECTION 6 - TURNTABLE

3121157

– JLG Lift –

6-41

DTC 219- RPM Higher Than Max Allowed
Governed Speed

• Max Govern Speed Override- Crankshaft Position Sen-

sor

• Check Condition-Engine Running

• Fault Condition-Engine speed greater than the max

governor override speed as defined in the diagnostic
calibration

• Corrective Action(s): Sound audible warning or illumi-

nate secondary warning lamp, reduce throttle to limit
speed. Recommend closed loop and adaptive learn
fueling correction remains active during fault.

• Non-emissions related fault

This fault will set anytime the engine RPM exceeds the
limit set in the diagnostic calibration for the latch time or
more. This speed overrides any higher max governor
speeds programmed by the user. This fault is designed to
help prevent engine or equipment damage.

The throttle will be lowered in order to govern the engine
to the speed set in the diagnostic calibration.

DTC 219- RPM Higher Than Max Allowed Governed
Speed (continued)

Diagnostic Aids

NOTE: If any other DTCs are present, diagnose those first.

• Ensure that no programmed governor speeds exceed

the limit set in the diagnostic calibration for Max Gov
Override Speed

• Check mechanical operation of the throttle actuator

PINK/WHITE

4

3

5

1

2

TAN/ORANGE

GREEN/RED

PURPLE/BLUE

BLACK/GREEN