Dtc 563- battery voltage (vbat) high, Dtc 563- battery voltage (vbat) high -50 – JLG 600SC_660SJC Service Manual User Manual

Page 196

Advertising
background image

SECTION 6 - TURNTABLE

6-50

– JLG Lift –

3121157

DTC 563- Battery Voltage (VBat) High

• System voltage to ECM

• Check Condition- Key on, Engine Cranking or Running

• Fault Condition- Battery voltage to ECM greater than x

volts while the engine is running as defined in the diag-
nostic calibration

• Corrective Action(s)- Illuminate MIL and/or sound audi-

ble warning or illuminate secondary warning lamp, dis-
able adaptive fueling correction for remainder of key
cycle

• Non-emissions related fault

The battery voltage powers the ECM and must be within
limits to correctly operate throttle acutator, power sup-
plies, and other powered devices that the ECM controls.

This fault will set if the ECM detects system voltage
greater than x volts while the engine is running or cranking
as defined in the diagnostic calibration.

BLACK

RED/TAN