SECTION 5 - JLG CONTROL SYSTEM

5-12

– JLG Lift–

3121322

remains on, even if the switch resets, until the igni-
tion input X1/1 (15) is recycled.

8.

The monitoring system will shut the engine down
(ouput to X1/7 is cut) if one of the following fault
input signals is present for 3 seconds:

a. No frequency on W - X2/10

b. Input on Oil - X2/1

c. Input on Temp - X2/3

9.

When there is a 24V output on X2/9 (50f), the engine
speed is increased by energizing the throttle sole-
noid. The circuit card generates this output from a
24V input on X1/3 (Aux2).

Table 5-12. Deutz Engine Control Board

OU

T

Start

Solenoi

d

Fu

e

l S

o

le

n

o

id

Throttle Solenoid (RPM

)

IN

X2/7

X2/8

X2/9

Ignition

X1/1

1

1

1

Start

X1/2

1

RPM

X1/3

1

Oil Pressure Switch (Ground)

X2/1

0

Alternator (D+)

X2/2

Temperature Switch (Ground)

X2/3

0

Air Filter Switch (Ground)

X2/4

0

Alternator (W)

X2/10

"0"

Glow Time (Ground) or
Vee Belt (Ground

X2/11

Power 24V

X2/5

+

+

+

Ground

X2/6

-

-

-

"0" = Zero frequency

Table 5-13. Deutz Engine

Connector X1

Ignition

X1/1

Start

X1/2

RPM

X1/3

Connector X2

Oil Pressure Switch (Ground)

X2/1

Alternator (D+)

X2/2

Temperature Switch (Ground)

X2/3

Air Filter Switch Ground)

X2/4

Power 24V

X2/5

Ground

X2/6

Start

X2/7

Fuel Solenoid

X2/8

RPM Solenoid

X2/9

Alternator (W)

X2/10

Glow Plug (Ground) or
Vee Belt (Ground)

X2/11

Through Line Connector

24V Power (direct to battery)

24V Power Alternator (B+)

Input

Output