SECTION 4 - HYDRAULICS

3121322

– JLG Lift –

4-9

15.

Use a spanner wrench to tighten the cylinder head
on the barrel.

16.

If applicable, after the cylinder has been reassem-
bled, the rod should be pushed all the way in (fully
retracted) prior to the reinstallation of any valve
block or load check valve.

NOTE: Refer to Figure 1-3., Torque Chart - (In/Lb - Ft/Lb).

(For ASTM Fasteners) to Figure 1-5., Torque Chart -
(Nm) - (For Metric Class Fasteners). f
or setscrew
torques.

Cylinder
Head

Barrel

Cylinder
Rod

Figure 4-21. Rod Assembly Installation

Cylinder
Barrel

Setscrews

Valve
Blocks

Figure 4-22. Valve Block Installation

NOTE: Lift Cylinder only.

Outrigger
Cylinder

Safety Valve

Limit Switch

NOTE: Outrigger Cylinders only.

Figure 4-23. Safety Valve and Limit Switch Installation