Rod assembly installation -9, Valve block installation -9, Safety valve and limit switch installation -9 – JLG 67SL Service Manual User Manual
Page 85
SECTION 4 - HYDRAULICS
3121322
– JLG Lift –
4-9
15.
Use a spanner wrench to tighten the cylinder head
on the barrel.
16.
If applicable, after the cylinder has been reassem-
bled, the rod should be pushed all the way in (fully
retracted) prior to the reinstallation of any valve
block or load check valve.
NOTE: Refer to Figure 1-3., Torque Chart - (In/Lb - Ft/Lb).
(For ASTM Fasteners) to Figure 1-5., Torque Chart -
(Nm) - (For Metric Class Fasteners). for setscrew
torques.
Cylinder
Head
Barrel
Cylinder
Rod
Figure 4-21. Rod Assembly Installation
Cylinder
Barrel
Setscrews
Valve
Blocks
Figure 4-22. Valve Block Installation
NOTE: Lift Cylinder only.
Outrigger
Cylinder
Safety Valve
Limit Switch
NOTE: Outrigger Cylinders only.
Figure 4-23. Safety Valve and Limit Switch Installation