SECTION 6 - GENERAL ELECTRICAL INFORMATION & SCHEMATICS

3121322

– JLG Lift –

6-3

Continuity Measurement

Current Measurement

Figure 6-3. Continuity Measurement

Figure 6-4. Current Measurement (DC)

• Some meters require a separate button press to

enable audible continuity testing

• Circuit power must be turned OFF before testing con-

tinuity

• Disconnect component from circuit before testing

• Use firm contact with meter leads

• First test meter and leads by touching leads together.

Meter should produce an audible alarm, indicating
continuity

• Set up the meter for the expected current range

• Be sure to connect the meter leads to the correct

jacks for the current range you have selected

• If meter is not auto ranging, set it to the correct range

(See multi meter’s operation manual)

• Use firm contact with meter leads