4 battery charging – JLG SSV10 Operator Manual User Manual

Page 33

Advertising
background image

SECTION 3 - MACHINE OPERATION

3121186

– JLG Lift –

3-5

3.4 BATTERY CHARGING

Battery Low Voltage Warning Indicators

The SSV10 Platform Control Console and Ground Control Station indicate battery low voltage at three (3) Warning Levels.

Table 3-2. Battery Low Voltage Warning Indicators.

WARNING

LEVEL

INDICATOR LOCATION

RESULT

ACTION REQUIRED TO CLEAR

FAULT

PLATFORM CONTROL LED

GROUND CONTROL LCD

LEVEL-1

• 3 LEDs/BARS Flashing with an

audible beep.

• Machine will Operate - No Con-

trol Functions Locked Out.

Charge batteries to a level of four (4)
LEDs/BARS or more before operat-
ing.

LEVEL-2

• 2 LEDs/BARS Flashing with an

audible beep.

• Platform Lift-UP Function is

Locked Out.

Charge batteries for a minimum of
four (4) continuous hours or eight (8)
LEDs/BARS lit before operating. (a)

LEVEL-3

• 1 LED/BAR Flashing with an

audible beep.

• Drive and Platform Lift-UP

Functions Locked Out.

Charge batteries for a minimum of
four (4) continuous hours or eight (8)
LEDs/BARS lit before operating. (a)

NOTE: (a) To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4 hours or until 8

bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level 2 or 3, batteries must be charged
until 8 bars are lit on the ground station LCD display to clear the fault code.

SECTION 3 - MACHINE OPERATION

3121186

– JLG Lift –

3-5

3.4 BATTERY CHARGING

Battery Low Voltage Warning Indicators

The SSV10 Platform Control Console and Ground Control Station indicate battery low voltage at three (3) Warning Levels.

Table 3-2. Battery Low Voltage Warning Indicators.

WARNING

LEVEL

INDICATOR LOCATION

RESULT

ACTION REQUIRED TO CLEAR

FAULT

PLATFORM CONTROL LED

GROUND CONTROL LCD

LEVEL-1

• 3 LEDs/BARS Flashing with an

audible beep.

• Machine will Operate - No Con-

trol Functions Locked Out.

Charge batteries to a level of four (4)
LEDs/BARS or more before operat-
ing.

LEVEL-2

• 2 LEDs/BARS Flashing with an

audible beep.

• Platform Lift-UP Function is

Locked Out.

Charge batteries for a minimum of
four (4) continuous hours or eight (8)
LEDs/BARS lit before operating. (a)

LEVEL-3

• 1 LED/BAR Flashing with an

audible beep.

• Drive and Platform Lift-UP

Functions Locked Out.

Charge batteries for a minimum of
four (4) continuous hours or eight (8)
LEDs/BARS lit before operating. (a)

NOTE: (a) To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4 hours or until 8

bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level 2 or 3, batteries must be charged
until 8 bars are lit on the ground station LCD display to clear the fault code.

Advertising