JLG SSV10 Operator Manual User Manual

Page 44

Advertising
background image

SECTION 3 - MACHINE OPERATION

3-16

– JLG Lift –

3121186

13

6

Traction Module

Over Temperature

(DRIVE Disabled)

Allow Drive System

Traction Module to Cool

Before Operating

17

7

Ground Control Module

Over Temperature

(Machine Stopped)

Allow Ground Control

Module to Cool

Before Operating

32

7

Pump Motor Over Current

(LIFT UP Disabled)

Platform Load
Over Capacity

34

Aux. #1 - Platform Gate

Open or No Pressure on the

Platform Footswitch.

Close Platform Gate or

Depress Platform Footswitch

during machine operation.

35

Aux. #1 - Platform Foot-
switch depressed during

Machine Power-up.

Do Not Press on Platform

Footswitch during Machine

Power-Up.

NOTE: The fault conditions shown in this table are fault conditions which the Operator may be able to resolve. Should a fault occur and be displayed on the

LCD screen which cannot be corrected at the Operator’s level, the problem must be referred to a mechanic qualified to repair this model of JLG Lift.
A complete table of Fault Codes is listed in the TroubleShooting Section of the Service and Maintenance Manual.

Table 3-3. LCD Display - Operating Fault Conditions (Continued)

FAULT

CODE

PLATFORM

LEDs

FLASHING

LCD SYMBOL SCREEN

LCD TEXT SCREEN

FAULT DESCRIPTION/
MACHINE CONDITION

TO CORRECT PROBLEM

13

13

00000.0

17

17

00000.0

32

32

00000.0

SECTION 3 - MACHINE OPERATION

3-16

– JLG Lift –

3121186

13

6

Traction Module

Over Temperature

(DRIVE Disabled)

Allow Drive System

Traction Module to Cool

Before Operating

17

7

Ground Control Module

Over Temperature

(Machine Stopped)

Allow Ground Control

Module to Cool

Before Operating

32

7

Pump Motor Over Current

(LIFT UP Disabled)

Platform Load
Over Capacity

34

Aux. #1 - Platform Gate

Open or No Pressure on the

Platform Footswitch.

Close Platform Gate or

Depress Platform Footswitch

during machine operation.

35

Aux. #1 - Platform Foot-
switch depressed during

Machine Power-up.

Do Not Press on Platform

Footswitch during Machine

Power-Up.

NOTE: The fault conditions shown in this table are fault conditions which the Operator may be able to resolve. Should a fault occur and be displayed on the

LCD screen which cannot be corrected at the Operator’s level, the problem must be referred to a mechanic qualified to repair this model of JLG Lift.
A complete table of Fault Codes is listed in the TroubleShooting Section of the Service and Maintenance Manual.

Table 3-3. LCD Display - Operating Fault Conditions (Continued)

FAULT

CODE

PLATFORM

LEDs

FLASHING

LCD SYMBOL SCREEN

LCD TEXT SCREEN

FAULT DESCRIPTION/
MACHINE CONDITION

TO CORRECT PROBLEM

13

13

00000.0

17

17

00000.0

32

32

00000.0

Advertising