2N® SmartGate UMTS parameters configuration

3.1

26

Installation and setting of SmartGate PCManager (Win7)

1. Connect 2N

®

SmartGate UMTS to the PC using USB connection. SmartGate

must be switched off.

2. After connecting is the virtual serial port in PC installed automatically. I case,

that the port doesn’t install automatically and unknown device is detected,

install drivers by using file: Drivers/win/CDM20814_Setup.exe.

3. Find the number of virtual port using Device manager. Look at setting of COM

ports and find port marked as USB Serial Port(COMn).

4. Install PCManagerSmG from CD.
5. Run SmartGate PCManager, select the language on the upper bar.
6. In menu Program select Setup. Set the COM port – local and select COM port

number according information from point 3.

Using of PCManager - basic

1. The main purpose of PCManager is setting of configuration and upgrade

firmware of SmartGate.

2. When the configuration in SmartGate should be changed, the configuration

must be first loaded from SmartGate, than edited using PCManager and finaly

loaded back to SmartGate.

3. The groups of parameters are listed is in the left window of the program. All

parameters are described in next part of this manual. There is interactive help

in PCManager for all parameters.

4. When you start with any operation which needs communication with

SmartGate, the gateway must be switched to special programming mode.

PCManager will show you the demand to switch the gateway off and on to set it

to this mode.

Further Data Handling Options

In addition to the 2N® SmartGate UMTS memory, settings can be saved in a PC file

and reloaded into the PCManager. This is recommended for backing up of current

configuration

Caution

n

The table Security includes the PIN code and service password. These

parameters have a special handling. They are not saved in a PC file for

security reasons. If you load a PC file into the PCManager and then into

SmartGate UMTS, the PIN and service password should not change unless
you change them manually before saving.