Table of Parameters

3.2

42

n

Accelerate connection establishing by allowing to terminate dialing with a #;

n

Modify the number to be dialed by removing and/or adding prefix.

The principle of table function is the same as in the FXS routing table. The call is

controlled according to parameters on the row with dialed number prefix match.

Remember to fill in the "Other prefixes" line for a number whose prefix is not found in

the table.

FXO calls route to

Function No.: 400

The main parameter for FXO calls routing. You can program 2N® SmartGate

UMTS as DialThru gateway, or as gateway for extension line of PBX.
DialThru gateway: Incoming ringing is immediately connected to FXS

interface. If function ME set, 2N® SmartGate UMTS starts to establish

UMTS/GSM call to ME number after defined number of rings. Routing table FXO

is not active.
Gateway for extension line of PBX: 2N® SmartGate UMTS detects incoming

ringing and Off-Hook the line after programmed number of rings, if it is possible

to make call to UMTS/GSM. 2N® SmartGate UMTS generate dial tone and after

dialing takes an action according to FXO routing table.

Setting options:

FXS - DialThru gateway (0)

GSM - gateway for extension line of PBX (1)

Default setting:

FXS - DialThru gateway

ME number

Function No.: 401

If you program 2N® SmartGate UMTS as DialThru gateway, fill in telephone

number for ME function. 2N® SmartGate UMTS starts to establish UMTS/GSM

call to ME number after defined number of rings. Then you can receive incoming

FXO call on telephone line or in UMTS/GSM network. Blank parameter disables

ME function.

Setting options:

0-16 characters (0-9,*,#,+)

Default setting:

blank

Number of rings to ME

Function No.: 402

If you program 2N® SmartGate UMTS as DialThru gateway and ME number is

filled in, 2N® SmartGate UMTS starts to establish UMTS/GSM call to ME number

after defined number of rings. Then you can receive incoming FXO call on

telephone line or in UMTS/GSM network.

Setting options:

0-255

Step:

1

Default setting:

1

Password for ME activation / disabling

Function No.: 403

If you program 2N® SmartGate UMTS as DialThru gateway and fill in ME

number, function ME is active. If you fill in password for ME activation/disabling,

you can activate/disable function ME without PC programming.

Off-Hook FXS line and dial PASSWORD plus

to disable the function.