Potential GSM/UMTS Troubles

All 2N GSM gateways work reliably under a long-time full load. The following problems
may be caused by GSM/UMTS networks:

The GSM/UMTS module(s) cannot log in, log in slowly, or log out occasionally.
This problem may be caused by any of the following situations:

 The GSM/UMTS signal is low. The minimum signal level should be

approximately -80dBm. If lower, change the antenna position or type!

 The GSM/UMTS cell (BTS) to which the GSM/UMTS modules are trying to

log in is overloaded. Change the antenna position or reduce the count of
the logged-in GSM/UMTS modules.

One of the GSM/UMTS modules is permanently logged-out or fails to make
outgoing calls:

 The problem indicates a GSM/UMTS network overload on the installation

site. To eliminate the problem, set the Relax delay parameter to 2
seconds
. If the GSM module fails to log in or rejects to make outgoing
GSM calls even after the gateway restart, consult your GSM provider for
your SIM card/GSM module availability.

The manufacturer shall not be held liable for any SIM card or provider service
unavailability in the case of a breach of the provider‟s SIM terms and conditions for
the SIM card use.

.