3.3.2 Networking Setup

Configure IP, SNMP, and alert settings on this page. Please fill in the IP information in the fields

under the TCP/IP header. Alternatively, enable DHCP to obtain IP address, gateway and

subnet mask from DHCP server automatically,

Fig. 3. 19

.

Fig. 3. 19

Enable SNMP and Alert Events by checking

“Enable”,

Fig. 3. 20

. Fill in SNMP information in

the fields under the SNMP header. Enable different Alert Events to send these events to a

SNMP Trap Server.

Cold/Warm Start

Triggers when the device is rebooted from the application level or physical level.

Link Down

Triggers when the TCP connection of the designated COM port is closed.

Link Up

Triggers when the TCP connection of the designated COM port is established.

Authentication Failure

Triggers when the username/password entered in the Telnet console or the WebUI is

incorrect.