3.4.2 TCP Client

By selecting the TCP Client mode, it means that a TCP Server program should be prepared to

connect to SE5002D. The following figure shows all the settings provided for the TCP Client.

 Click on the

“COM1” link on the left hand side.

 Select TCP Client.

 Enter the preferred Destination IP and Port. This should match the IP settings of the

TCP Server program.

Connect Rule; decide how SE5002D should connect to the TCP Server here. If

SE5002D should always keep the connection, select TCP Connect on Power-on. This

means SE5002D would connect to the TCP Server program when SE5002D is powered

on. By default, TCP Connect on Any Serial Character is selected. This means that

SE5002D-Fx would only connect to the TCP Server program when it receives data from

its serial interface. If TCP Connect on Any Serial Character is selected, there are two

additional options to change, which are Serial Inactivity Time Before Disconnect and

Waiting Time Between Re-connect Attempts. Serial Inactivity Time Before

Disconnect determines how long SE5002D should wait before closing a TCP

connection if there is no incoming serial data. The default value is 40 seconds. Waiting

Time Between Re-connect Attempts determines the time SE5002D should wait before

it tries to establish a connection with a TCP Server again if it fails to connect to the TCP

Server. The default value is 1 minute.

TCP Keep-Alive; Specifies the interval in the

“Idle Time Before Sending TCP Alive

Packet

to force SE5002D to send TCP Keep-Alive packets in the set interval to prevent

disconnection from the client. Note that this field is has a 10 multiplier, so the default

value 4 means to send Keep-Alive packets every 40 seconds.

TCP Inactivity Timeout; Specifies the value in

“TCP Inactivity Time Before

Disconnect

to force SE5002D actively close a TCP connection after some specific

inactivity time (no packets). The default value is 0, which means the SE5002D would

never actively close an established connection.

 Scroll to the bottom of the page and click on

“Save Configuration” button to save the

changes.