3.4.1 TCP Server

SE5002D is configured by default as TCP Server mode, there are additional connection

settings that can be configured. By selecting the TCP Server mode, a TCP Client program

should be prepared to connect to SE5002D.

 Click on

“COM1” link on the left hand side.

 Select TCP Server. TCP Server is the default link mode.

 Enter the Local Listening Port. This is the port specified in the TCP Client program

connecting to the serial device server. The default local port is 4660.

IP Filter; only the designated IP address will be able to access the COM port if this option

is enabled. This option is disabled by default.

TCP Keep-Alive; specify the interval in the

“Idle Time Before Sending TCP Alive

Packet

to force SE5002D to send TCP Keep-Alive packets in the set interval to prevent

disconnection from the client. Note that this field has a 10 multiplier, so the default value

4 means to send Keep-Alive packets every 40 seconds.

TCP Inactivity Timeout; specify the value in

“TCP Inactivity Time Before Disconnect”

to force SE5002D actively close a TCP connection after some specific inactivity time (no

packets). The default value is 0, which means SE5002D would never actively close an

established connection.