L2

L1

L3

2MOL

MOTOR

WASH

440V

120V

2M

4CR

1MOL

STOP

1CR

START

1M

120V CONTROLS

3MOL

RINSE

MOTOR

3M

T1

3MOL

RFSW

W

R

DRIVE

MOTOR

FU1

FU2

DSS

1MOL

1M

ELECTRIC

USN-72

701697

C

J.NEWTON

23MAR00

1

1

2MOL

TSK

FRSW

TSR

3CR

2CR

RT

WFSW

WT

SET FOR 5 SECONDS

SET FOR 5 SECONDS

TLS

MSW

2CR

3CR

5CR

L1

L3

PL

CB

SW

OFF

ON

6CR

7CR

TSW

SEE NOTE 2

HC1

10kW

10kW

10kW

2L1 2L2 2L3

HC2

10kW

10kW

TO CUSTOMER

DISCONNECT SWITCH

FUSED FOR 50A MAX. AT

440/60/3.

HLWT

HLRT

TO CUSTOMER

DISCONNECT SWITCH

FUSED FOR 50A MAX. AT

440/60/3.

!!!!!! WARNING !!!!!!

MULTIPLE POWER SOURCES ARE PRESENT

IN THIS CABINET. DISCONNECT ALL POWER

SOURCES PRIOR TO SERVICING.

!!!!!! WARNING !!!!!!

MULTIPLE POWER SOURCES ARE PRESENT

IN THIS CABINET. DISCONNECT ALL POWER

SOURCES PRIOR TO SERVICING.

TKL

PRIME

WASH TANK

HEATERS

HEATERS

RINSE TANK

A

TANK HEAT ADDED TO MOTORS AND CONTROL CIRCUIT

6JUNE00 JCN

SEE NOTE 1

4MOL

4M

MOTOR

MRA

(IF USED)

NOTES

1. REMOVE JUMPER ACROSS WIRES 70

AND 9 WHEN RACK ADVANCE TABLE IS

USED.

2. REMOVE JUMPER ACROSS N.O. 5CR

CONTACT WHEN TABLE LIMIT SWITCH IS

USED.

MRA

4MOL

IF USED

(IF USED)

(IF USED)

B

MRA TO BE NC IN NORMAL POSITION

16OCT00 JCN

TB4

TB5

C

CHANGED WIRE NUMBERS TO MATCH TERMINAL BLOCKS

06OCT03 JAM

HC2

HC1

1CR

2CR

3CR

4CR

5CR

6CR

7CR

FRV

1M

2M

3M

4M

GND

RINSE AID/

SANI SIGNAL

1

47

46

45

2

15

1

2

6

5

4

3

49
50

48

21

44

42
43

8

CUSTOMER TO SUPPLY RATED VOLTAGE/PHASE/Hz,

AS SPECIFIED PER ORDER,TO DISCONNECT SWITCH.

ALL POWER SUPPLIED TO EACH CONNECTION POINT

MUST COMPLY WITH ALL LOCAL ELECTRIC CODES.

BY

DATE

DESCRIPTION

REV.

B

REV.

The Dishwashing Machine Specialists

SCALE

DR.BY
DATE

SHEET

OF

REV.

DESCRIPTION

DATE

BY

P1

P2

20

5

M

CLUTCH

6

2

4

1

7

8

OFF DELAY

5

OFF DELAY

2

7

M

8

6

CLUTCH

1

4

L3

L1
L2

L1
L2
L3

L1
L2
L3

33

41

39
40

37
38

36

35

34

17

3A

23

7

9

10

11

12

13

14

95

4

96

25

29

30

26

3

3C

22

DIAGRAM STATE

END OF CYCLE

TANKS EMPTY

DOORS CLOSED

POWER OFF

2

2B

31

32

51

SIGNAL

DETERGENT

4

8

3

62B

61B

62A

60B

61A

60A

63B

65B

64B

64A

65A

63A

64C

65C

63C

16

GND

97

4

98

98

70

L1

L3

L2

51

53

52

54

56

55

99

28

2E

19

4

22

WASH TANK DOOR SAFETY SWITCH

WFSW
WT

W

WASH TANK FLOAT SWITCH
WASH TANK FLOAT TIMER

*

MRA CONTACTOR

4M

LOW TEMPERATURE CUT-OFF THERMOSTAT

RINSE TANK DOOR SAFETY SWITCH

MACHINE RACK ADVANCE LIMIT SWITCH

BOOSTER HEATER CONTACTOR

WASH TANK HEAT CONTACTOR
RINSE TANK HEAT CONTACTOR

MRA

RFSW

TSR
TSW

TSK

TSB

TLS

TKL

R

T1

SW

RT

PL

BOOSTER THERMOSTAT

TABLE LIMIT SWITCH

LOW TEMP INDICATOR LIGHT

RINSE TANK THERMOSTAT
WASH TANK THERMOSTAT

*

440V:120V TRANSFORMER

RINSE TANK FLOAT TIMER
POWER SWITCH

POWER ON LIGHT
RINSE TANK FLOAT SWITCH

*
*

*

*

4MOL

HLWT

HLRT

FRSW

MSW

HC1
HC2

FU-

FRV

DSS

CB

BC1

MOTOR STOP SWITCH

HIGH LIMIT RINSE TANK
HIGH LIMIT WASH TANK

FUSE-TRASNSFORMER

*

*

*

MRA MOTOR OVERLOAD

CIRCUIT BREAKER
DOOR SAFETY SWITCH

FINAL RINSE FILL VALVE

FINAL RINSE SWITCH

*

*

*

WASH TANK FLOAT SWITCH RELAY
RINSE TANK FLOAT SWITCH RELAY

DOOR SAFETY SWITCH HOLD-IN RELAY
WASH TANK FLOAT HOLD-IN RELAY
RINSE TANK FLOAT HOLD-IN RELAY

1MOL

2MOL

3MOL

3M

2M

1M

6CR
7CR

5CR

3CR
4CR

2CR

DRIVE CONTACTOR
DRIVE MOTOR OVERLOAD
WASH CONTACTOR
WASH MOTOR OVERLOAD
RINSE CONTACTOR
RINSE MOTOR OVERLOAD

*

*

*

*

*

*

*

FINAL RINSE SWITCH RELAY
TABLE LIMIT SWITCH RELAY

*

*

*

*
*

*

1CR

*

*

PARTS LOCATED IN CONTROL PANEL

TB7

RINSE HEATER TERMINAL BLOCK

TB6

WASH HEATER TERMINAL BLOCK

60

62

61

65

63

64

2A

2C

2D

2

2

2

2

2

2

2

2

2

2

2

3

3

3

3

3B

3D

3

3

97

4

8

15

2

2

2

2

2

32

31

30

29

17

20

GND