5 electrical power requirements – CHAMPION USN72 User Manual

Page 22

Advertising
background image

Part 1: GENERAL SPECIFICATIONS

4

1.5 Electrical Power Requirements

1.5.1 Power Requirements for Steam Heat

Machine Full Load Amps 6.9A

Operating Currents (440V/60/3 Supply)

Steam Heated

Wash motor

2.7 Amps

Rinse motor

2.7 Amps

Drive motor

0.4 Amps

Control Circuit

1.1 Amps

1.5.2 Power Requirements for Electric Heat

Machine Full Load Amps 6.9A

Operating Currents (440V/60/3 Supply)

Wash motor

2.7 Amps

Rinse motor

2.7 Amps

Drive motor

0.4 Amps

Control Circuit

1.1 Amps

Each heat circuit has a separate power source.

Circuit

Voltage

Booster Rise

Machine

Power Requirement

Hz/Ph

(Steam)

Full Load Amps (125% Service Factor)

Motor/Control

440/60/3

70

°

6.9 Amps

9.0 Amps

Heat

Voltage

KW

Amps

Power Requirement

Circuit

Hz/Ph (Electric)

Full Load

(125% Service Factor)

Wash

tank heat

440/60/3

20KW

27 Amps

33 Amps

Power Rinse

tank heat

440/60/3

30KW

40 Amps

50 Amps

Final Rinse

Booster (40

°

rise)

(One cannister)

440/60/3

37.8KW

49.6 Amps

62 Amps

Final Rinse

Booster (70

°

rise)

(Two cannisters)

Cannister 1

440/60/3

32.8KW

43 Amps

53.8 Amps

Cannister 2

440/60/3

32.8KW

43 Amps

53.8 Amps

Total KW for 70

°

rise is 65.6 KW

Advertising