C57 modified electrical connections – CHAMPION USN72 User Manual

Page 173

Advertising
background image

11

USN72 Booster Conversion Instructions - Kit P/N 453393

C57 Modified Electrical Connections

1. Refer to the Installation &

Operation Manual for the

electrical specifications for the

C57 Modified booster and connect

the incoming power service at

the main terminal block located

on the left-side of booster cabinet.

2. Refer to the wiring diagram at the

bottom of this page and connect

the Low Temperature Interlock wires

that were previously removed from the

Champion CH-60 booster.

3. The Low Temperature

Interlock connection block

is located on the right-side of the

booster cabinet.

4. Close the booster cabinet and

refer to the Installation and

Operating Manual for the

C57 Modified booster.

Main

Terminal

Block

The main terminal block is located on the left-side

of the booster cabinet interior.

The Low temperature interlock block is located on

the right-side of the booster cabinet interior.

NO

NO

NC

COM

COM

NC

TEMPERATURE INTERLOCK

Low Temperature Interlock Switch Wiring Diagram

Advertising