Service bulletin – CHAMPION USN72 User Manual

Page 162

Advertising
background image

1

20

Part 6: REPLACEMENT PARTS

Part 8: SPECIAL INSERTS

P.O. Box 4146
Winston-Salem, NC 27115
Tel: 336-661-1556
Fax: 336-661-1660
Tel: 800-858-4477

SERVICE BULLETIN

Stemco Thermostat Replacement

Stemco Replaces Fenwall

January 20, 2003

REPLACING FENWAL THERMOST

P/N 100128 WITH STEMCO THERMOSTAT

P/N 109069

For all Navy machines that are purchased with steam heated boosters. This notification is

for the replacement of the thermostat in those boosters. To ensure that the thermostat is

placed properly into the booster tank, please follow the diagram listed below. When replac-

ing the the thermostat use part number 109069.

1. Mark off the measurement of 12 inches from the end of the bulb. This will be at the end

of the 1/2" nut that mounts inside of the tee.

2. Insert the thermostat bulb 12 inches into the booster. Ensure that the bulb is inside one

of the copper water tubes and not coiled up inside of the head. Place plumbers putty on

the 1/2" nut. Tighten down the 1/2" nut inside of the tee.

3. Push the remaining capillary tube to the marking and tighten down the compression nut

so as to lock down the furrell on the capillary. The thermostat replacement is now

complete.

Navy Steam Boosters

12 Inches

12 inches

Advertising