Adjusting thermostat set-point – CHAMPION USN72 User Manual

Page 182

Advertising
background image

20

USN72 Booster Conversion Instructions - Kit P/N 453393

Form No. EBOOSTERM-0406

27

ADJUSTING THERMOSTAT SET-POINT

Figure 19. Thermostat Adjustment

GENERAL

WARNING

To avoid any injury or damage to the booster

heater turn the power OFF at the disconnect

switch/circuit breaker and allow to cool before

performing any maintenance or adjustments.

THERMOSTAT

Thermostat Adjustment

The thermostat is factory calibrated to produce

temperatures of 185°-190°F (85°-88°C). If

adjustment or recalibration is required use the

following procedure. (See Figures 18 and 19.)

NOTE: Low Temperature Dishmachines require the

thermostat(s) to be adjusted to 140°-150°F

(60°-66°C).

1. Remove the access cover.

To

lower the temperature setpoint, turn the outer

adjustment screw counterclockwise.

To

raise the temperature setpoint, turn the outer

adjustment screw clockwise.

NOTE: 1/6 turn of the outer screw equals 12°F

(6.7°C).

If recalibration is necessary, with the outer screw at

high stop turn inner adjustment screw clockwise to

raise the set point.

NOTE: 1/6 turn of the inner screw equals 8°F

(4.4°C).

HIGH TEMPERA TURE LIMIT SAFETY

SWITCH

All Hatco Electric Booster Water Heaters are

equipped with a manually reset high temperature

limit safety switch. If the temperature of the water in

the heater exceeds 210°F (99°C) the safety switch

will shut off the power. The switch must be manually

reset by pushing the red button.

If the high temperature limit safety switch needs to

be reset use the following procedure

(See Figures 18 and 20.):

1. Remove access cover.

2. Push red reset button.

3. If tripping repeats, call an Authorized Service

Agent.

Outer Screw

Inner Screw

Figure 18. Access Cover for Thermostat(s) and High

Temperature Limit Safety Switch

Access Cover

Figure 20. High Temperature Limit Safety Switch

Red Reset Button