28

Figure 9 – Input Voltage Selection


Turn-On Checkout

When you turn on the electronic load, the front-panel display will light up briefly while the
electronic load performs its power-on self-test. The following table shows the procedure of the
self-test.

Mainframe VFD Display

Description

BOIS Ver 1.20

VFD displays software version

SYSTEM SELF TEST

System self-check

CH1/2/3/4/5/6/7/8
SCAN…
□7□5□3□1


Detecting all installed modules

e.g.:CH01 CV OFF
Vdc=0.0000V Adc=0.0000A
Wdc=

0.00W

Displays information of channel 1 or the leftmost channel.
Use up and down key to select other channels.

WARNING: Your electronic load is equipped with a 3-wire grounding type power cord;
the third conductor being ground. The electronic load is grounded only when the
power-line cord is plugged into an appropriate receptacle. Do not operate your power
supply without adequate cabinet ground connection.

Documentation Provided By HMC Electronics

33 Springdale Ave. Canton, MA 02021

http://www.hmcelectronics.com

(800) 482-4440