HMC Electronics MDL Series BK Precision DC Electronic Load System Module User Manual

Page 54

Advertising
background image

54

12.

Press Esc key to exit.

CH01 CC OFF
Vdc = 0.0000V
Adc = 0.0000A
Wdc = 0.00W

13.

Press Shift + ⑦ to enter System menu. Press  key to select <Trigger

source> and press Enter. Select <Manual> and press Enter to confirm.

MANUAL
EXTERNAL
HOLD
BUS
TIMER

14.

Press Esc key to exit.

CH01 CC OFF
Vdc = 0.0000V
Adc = 0.0000A
Wdc = 0.00W

15.

Press On/Off key to turn on the electronic load’s input.

CH01 CC ON
Vdc = 0.0000V
Adc = 0.0000A
Wdc = 0.00W

16.

Press Tran key on channel 1 module to enable transient operation.

17.

Press Trig key on mainframe panel to trigger transient operation.



Transient Operation Programming Example
If in remote control mode, you can use the following example commands for transient operation
(refer to MDL Series Programming Guide for more information).

CURRent:TRANsient:MODE CONTinous
CURRent:TRANsient:ALEVel 10
CURRent:TRANsient:AWIDth 0.2ms
CURRent:TRANsent:BLEVel 2
CURRent:TRANsient:BWIDth 0.3ms
TRANsient ON
TRIGger:IMMediate


Documentation Provided By HMC Electronics