Setting CV, CC, CR, CW, CZ Mode

The following procedure will show you a basic example of how to set up your operation mode from
the front panel.

Panel Operations

VFD Display

1.

Power on the electronic load.

Self-test

2.

Press  keys to select the channel to be edited, such as channel 1.

CH01 CC OFF
Vdc=0.0000V
Adc=0.0000A
Wdc=0.00W

3.

Press Setup key to enter the channel setup menu, press Enter key to

enter the <Mode> selection menu and press  key to select CV, CC, CR,
CW, or CZ mode. Press Enter key to confirm.

CH01
Mode=CC
RANGE=HIGH
Iset=9.000A

4.

Press  key to select <Range> selection menu. Press Enter key to enter

the <Range> selection menu and press  key to choose <Low Range> or
<High Range>. Press Enter key to confirm.

CH01
HIGH RANGE
LOW RANGE

5.

Press  key to select the voltage setting <Vset>, current setting <Iset>,

resistance setting <Rset>, power setting, or impedance setting and press
Enter key to confirm.

CH01
Const Current
Set= 1.25A

6.

Press  key to select the rise slope setting <∫>. Input value and press

Enter key to confirm. (CC mode only)

CH01
Rise Speed Set
= 1.00A/Us

7.

Press  key to select the fall slope setting <∫>. Input value and press

Enter key to confirm. (CC mode only)

CH01
Fall Speed Set
= 2.00A/Us

8.

Press Esc key to exit.

9.

Press On/Off key to turn on the load’s input.

CH1 CC ON
Vdc=0.0000V
Adc=0.0000A
Wdc=0.00W