Table 3 - Module Terminal Pinout

Pin

Signal

Description

1

GND

Ground

2

VF

Voltage fault indication terminal

3

DI

Digital input terminal

4

DO

Digital output terminal

I OUT

Current monitoring output

5

SENSE +

Voltage remote measuring terminal (+)

6

SENSE -

Voltage remote measuring terminal (-)

7

EXT_PRG+

External analog controlling terminal (+)

8

EXT_PRG-

External analog controlling terminal (-)




Voltage Failure Indication

When the electronic load is under OVP or reverse protection condition, pin 2 (VF) will output a high
level signal.

Current Monitoring

The current monitoring terminal will output 0-10 V analog signal accordingly to 0 - full range of the
input current. You can connect an external voltmeter or an oscilloscope to display the input
current’s change.

Digital I/O

Digital I/O is pin 3 and pin 4 shown in Figure 31 and only used in remote control. The digital input
terminal (pin 3) can detect a high/low level signal. The digital output terminal (pin 4) can output a
TTL high/low level signal. It is a universal output terminal and can be used to control an external
instrument.