Vfd indicator function description – HMC Electronics MDL Series BK Precision DC Electronic Load System Module User Manual

Page 49

Advertising
background image

49

VFD Indicator Function Description

The detailed illustration of the VFD and all indicator functions are as follows:

Figure 24 - Load Module VFD Panel


L/R
is the indicator of the dual-channel module’s left/right channel. If you want to edit left/right
channel parameters, first select the channel using the L/R key. Single-channel module will always
display R.

OFF indicates that the module input is off. When module input is enabled, OFF indicator will turn
off.

CC/CV/CR/CW/CZ indicates the module’s operating mode.

VFD display screen shows four lines of numbers. The first line shows the measured voltage value.
The second line shows the measured current value. The third line shows the measured circuit’s
power value. The fourth line shows the setup value, and users can set A/V/Ω value here.

Short is displayed when short circuit function is enabled on the module.

Tran is displayed when TRANSIENT mode is enabled on the module.

List is displayed when selecting LIST mode in the Configuration menu.

Sense is enabled in remote sense function. There is no need to set this in the menu, as you only
need to link the circuit to remote sense terminals and ‘Sense’ will be displayed.

Documentation Provided By HMC Electronics

33 Springdale Ave. Canton, MA 02021

http://www.hmcelectronics.com

(800) 482-4440

Advertising