1 device data, 2 power controller, Device data – JUMO 709062 TYA 202 - Three-Phase Power Controller Operating Manual User Manual
Page 52: Power controller, Scr control, 5 configuration

5 Configuration
50
2012-12-31/00561073 [SCR power switch TYA202]
5.1.1
Device data
Basic settings for display and temperature unit.
5.1.2
Power controller
Settings for the switching behavior of the power controller in the system.
Value / settings
Description
Temperature unit
°C
Defines the unit for the displayed temperatures, such as the
device temperature.
°F
Display contrast
0 to 50 to 100 %
Bright/dark contrast setting
Switch-off
Display lighting
0000 to 1440 min
After the set number of minutes, the background lighting of
the display switches off. Power LED (green) flashes.
0000 means: lighting is always switched on
Apply factory set-
tings
Apply now?
If the PGM key is pressed, the factory settings are restored.
k
/ bold = factory setting
Value / settings
Description
SCR control
Continuous (power
controller)
The power controller provides the power for the load continu-
ously depending on the default setpoint value.
Logic (switch)
The power controller acts like a switch and provides the power
by either switching ON or OFF.
k
/ bold = factory setting