10

Lenze 13466183 EDBSC03 v7

Installation

a

4 x M4
1.2 Nm
10 lb-in

4 x M6
2.8 Nm
24 lb-in

c

a1

b1

b2

s2

s2

s1

s1

b

A
B
C

D

smd402

Type

a

[mm]

a1

[mm]

b

[mm]

b1

[mm]

b2

[mm]

c

[mm]

s1

[mm]

s2

[mm]

m

[kg]

ESMD371C2YXA, ESMD371C4TXA

93

84

146

128

17

100

15

50

0.6

ESMD751C2YXA, ESMD751C4TXA

93

84

146

128

17

120

15

50

0.9

ESMD112C4TXA

93

84

146

128

17

146

15

50

1.0

ESMD112C2YXA

114

105

146

128

17

133

15

50

1.4

ESMD152C4TXA

114

105

146

128

17

122

15

50

1.4

ESMD222C4TXA

114

105

146

128

17

139

15

50

1.4

ESMD152C2YXA, ESMD222C2YXA

ESMD302C2TXA

ESMD302C4TXA

114

105

146

128

17

171

15

50

2.0

ESMD402C2TXA

ESMD402C4TXA, ESMD552C4TXA

114

105

146

100

17

171

15

50

2.0

ESMD552C2TXA, ESMD752C2TXA

ESMD752C4TXA, ESMD113C4TXA

146

137

197

140

17

182

30

100

3.2

ESMD113C2TXA, ESMD153C2TXA

ESMD153C4TXA... ESMD223C4TXA 195

183

248

183

23

203

30

100

6.4

3

Installation

3.1

Mechanical Installation

3.1.1 Dimensions and Mounting

WARNING!

Drives must not be installed where subjected to adverse environmental conditions

such as: combustible, oily, or hazardous vapors or dust; excessive moisture;

excessive vibration or excessive temperatures. Contact Lenze for more information.