Installation, 4 control terminals – Lenze SMD 0-37kW-22kW User Manual

Page 13

Advertising
background image

Lenze 13466184 EDBSL03 v20

EN, DE, FR, IT, ES

11

Installation

Terminal Data for control connections

(printed in bold = Lenze setting)

71

RS-485 serial communication input

RXB/TXB (B+)

72

RS-485 serial communication input

RXA/TXA (A-)

7

Reference potential

8

Analog input

0 … 10 V

(changeable under C34)

input resistance: >50 kΩ

(with current signal: 250Ω)

9

Internal DC supply for setpoint potentiometer

+10 V, max. 10 mA

20

Internal DC supply for digital inputs

+12 V, max. 20 mA

28

Digital input Start/Stop

LOW = Stop HIGH = Run Enable

R

i

= 3.3 k

E1

Digital input configurable with CE1

Activate fixed setpoint 1 (JOG1)

HIGH = JOG1 active

E2

Digital input configurable with CE2

Direction of rotation

LOW = CW rotation

HIGH = CCW rotation

E3

Digital input configurable with CE3

Activate DC injection brake (DCB)

HIGH = DCB active

A1

Digital output configurable with c17

DC 24 V / 50 mA; NPN

62

Analog output configurable with c08 & c11

K14

Relay output (normally-open contact)

Configurable with C08

Fault (TRIP)

AC 250 V / 3 A

DC 24 V / 2 A … 240 V / 0.22 A

K12

LOW = 0 … +3 V, HIGH = +12 … +30 V

Protection against contact

• All terminals have basic isolation (single insulating distance)

• Protection against contact can only be ensured by additional measures (i.e. double insulation)

STOP!

In the case of a Spinning Motor:

To bring free-wheeling loads such as fans to a rest before starting the drive, use the DC

injection braking function (“Auto-DCB”). Starting a drive into a freewheeling motor creates

a direct short-circuit and may result in damage to the drive.
Confirm motor suitability for use with DC injection braking.

3.2.4 Control terminals

STOP!

If the kVA rating of the AC supply transformer is greater than 10 times the input kVA rating of the drive(s),

an isolation transformer or 2-3% input line reactor must be added to the line side of the drive(s).

Advertising