Lenze 13466184 EDBSL03 v20

EN, DE, FR, IT, ES

Technical data

Conformity

CE

Low Voltage Directive (2006/95/EC)

Approvals

UL 508C

Underwriters Laboratories - Power Conversion Equipment

Max. permissible motor cable
length

(1)

shielded:

50 m (low-capacitance)

unshielded:

100 m

Input voltage phase imbalance

< 2%

Humidity

< 95% non-condensing

Output frequency

0...500 Hz

Environmental conditions

Class 3K3 to EN 50178

Temperature range

Transport

-25 … +70 °C

Storage

-20 … +70 °C

Operation

0 … +55 °C (with 2.5 %/°C current derating above +40 °C)

Installation height

0 … 4000 m a.m.s.l. (with 5 %/1000 m current derating above 1000 m a.m.s.l.)

Vibration resistance

acceleration resistant up to 0.7 g

Earth leakage current

> 3.5 mA to PE

Enclosure (EN 60529)

IP 20

Protection measures against

short circuit, earth fault, overvoltage, motor stalling, motor overload

Operation in public supply networks
(Limitation of harmonic currents)

Total power

connected to

the mains

Compliance with the requirements

(2)

EN 61000-3-2

< 0.5 kW

With mains choke

0.5 … 1 kW With active filter (in preparation)

> 1 kW

Without additional measures

EN 61000-3-12

16 ... 75A

Additional measures are required for compliance with the

standard

Supply Conditions

AC Mains

Direct Connection

Power System

TT

For central grounded systems operation is permitted without

restrictions

TN

For corner grounded 400/500V systems, operation is possible,

but reinforced insulation to control circuits is compromised.

IT Mains

IT Mains power systems are not supported.

(1) For compliance with EMC regulations, the permissible cable lengths may change.