Wiring of system bus (can), 6electrical installation – Lenze EMF2178IB User Manual

Page 58

Advertising
background image

6

Electrical installation

Wiring of system bus (CAN)

EDKMF2178IB DE/EN/FR 6.0

58

l

h2_can−Bus−Leitungslaenge_2178

Wiring of system bus (CAN)

EMF2178IB

GND

V+

CAN_L

CAN_H

SHLD

120

W

CAN

LOW

GND

HIGH

+

+

GND

120

W

2178CAN002

Fig. 4

Connection to the plug connector

Terminal data

Area

Values

Electrical connection

Plug connector with screw connection

Possible connections

rigid:

1.5 mm

2

(AWG 16)

flexible:

without wire end ferrule
1.5 mm

2

(AWG 16)

with wire end ferrule, without plastic sleeve
1.5 mm

2

(AWG 16)

with wire end ferrule, with plastic sleeve
1.5 mm

2

(AWG 16)

Tightening torque

0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in)

Stripping length

6 mm