3 technical data, 1 general data/operating conditions, Technical data – Lenze MDSLS Servo spindle motor User Manual

Page 15: 3technical data

Advertising
background image

Technical data

General data/operating conditions

3



15

BA 33.0003 EN 1.0

3

Technical data

3.1

General data/operating conditions

Range

Values

Mounting positions

Can be used in all mounting positions

Vertical arrangements to DIN-IEC

34 Part 7 are possible if they meet

the designs

Enclosure

See nameplate

Enclosures apply only to horizontal

installation

Thermal class

F (155 °C) to DIN-IEC 34 / VDE

0530

Exceeding the temperature limit

weakens or destroys the insulation

Tropical protection

Not guaranteed

Permissible

Versions

temperature range

z

Non-ventilated without or

with spring-operated brake

-20 °C ... +40 °C Without power reduction

Permissible installation

height h

h ≤ 1000 m AMSL

1000 m AMSL < h ≤ 2000 m

AMSL

Without power reduction

With power reduction

Certifications

CE Low-Voltage Directive

Permissible voltage load 1.5 kV peak value

5 kV/µs rate of rise

Humidity

Up to 85% without moisture

condensation

Vibration

Up to 2.0 g, if no resonances are excited, e.g. the fan.