3 technical data, 1 general data/operating conditions, Technical data – Lenze MDSLS Servo spindle motor User Manual
Page 15: 3technical data
Technical data
General data/operating conditions
3
15
BA 33.0003 EN 1.0
3
Technical data
3.1
General data/operating conditions
Range
Values
Mounting positions
Can be used in all mounting positions
Vertical arrangements to DIN-IEC
34 Part 7 are possible if they meet
the designs
Enclosure
See nameplate
Enclosures apply only to horizontal
installation
Thermal class
F (155 °C) to DIN-IEC 34 / VDE
0530
Exceeding the temperature limit
weakens or destroys the insulation
Tropical protection
Not guaranteed
Permissible
Versions
temperature range
z
Non-ventilated without or
with spring-operated brake
-20 °C ... +40 °C Without power reduction
Permissible installation
height h
h ≤ 1000 m AMSL
1000 m AMSL < h ≤ 2000 m
AMSL
Without power reduction
With power reduction
Certifications
CE Low-Voltage Directive
Permissible voltage load 1.5 kV peak value
5 kV/µs rate of rise
Humidity
Up to 85% without moisture
condensation
Vibration
Up to 2.0 g, if no resonances are excited, e.g. the fan.