Troubleshooting and fault elimination

8



33

BA 33.0003 EN 1.0

Fault

Cause

Remedy

Motor becomes too warm

Can only be determined

Cooling-air volume is too low,

cooling-air passages are blocked

Ensure that cooling-air inlet and outlet are unrestricted

Can only be determined

through measurements;

permissible surface

Cooling air is prewarmed

Ensure that fresh air is present

permissible surface

temperatures:

z

non-ventilated motors

up to 140 °C

Overload, with normal mains voltage

the current is too high and the speed

too low

Install a larger drive (determination through power

measurement)

up to 140 C

z

forced- or self-ventilated

motors up to 110 °C

Exceeded rated operating mode (S1

to S8 DIN 57530)

Adjust rated operating mode to the specified operating

conditions. Determination of correct drive by expert or Lenze

customer service

Loose contact in supply cable

(temporary single-phase operation!)

Correct loose contact

Fuse is blown (single-phase

operation!)

Replace fuse

Motor does not start

Voltage supply interrupted

z

Check error message at drive controller

z

Check electrical connection (E Ch. 5)

Controller inhibited

z

Check display at drive controller

z

Check controller enable

Fuse is blown

Replace fuse

Motor protection responded

Check motor protection for correct setting and adjust it

Motor contactor does not engage,

fault in the control

Check control of motor contactor and remove fault

Resolver cable is interrupted

z

Check error message at drive controller

z

Check resolver cable

Brake does not release

Check electrical connection
Check air gap (see Brake operating instructions)
Check continuity of magnetic coil

Drive is blocked

Check components for easy movement, remove foreign bodies

if necessary

Motor cable polarity is reversed

Check electrical connection

Motor stops suddenly and

does not restart

z

Motor cable polarity is reversed

or

z

Polarity of resolver cable is

reversed

z

Align the phases at the connection of the motor cable

and

z

Perform the correct connection of the encoder

Overtemperature protector switch

responds

z

Let the motor cool off

– Reduce loading through longer acceleration times

Overload monitoring of the inverter

responds

z

Check settings at the drive controller

z

Reduce loading from longer acceleration times

Wrong direction of rotation

of the motor, correct

display at controller

Reversed motor cable and resolver

cable

z

Swapping two phases of the motor cable

and

z

+COS/-COS connections of the resolver connection

Uneven running

Insufficient shielding of motor or

resolver cable

Check shielding and earthing (E Ch. 5.1.1)

Drive controller gain too large

Adjust the gains of the controllers (see Drive controller

operating instructions)

Vibrations

Insufficient alignment of the drive

train

Realign the machine set, check foundation if necessary

Loose fixing screws

Check and secure screwed connections

Running noises

Foreign bodies inside the motor

Repair by manufacturer, if necessary

g

Bearing damage, spindle damage

Repair by manufacturer, if necessary

Surface

temperature > 140 °C

Overload of drive

z

Check overload and reduce through longer acceleration

times, if necessary

z

Check winding temperature (E Ch. 9.2.2)

Heat removal restricted due to

deposit build-up

Clean surface and cooling ribs of the drives