Commissioning 6 – Lenze MDSLS Servo spindle motor User Manual
Page 28
![background image](/manuals/565992/28/background.png)
Commissioning
6
28
BA 33.0003 EN 1.0
Implementation of function block interconnection
Code list
Code
Function block
Name
Current
C0338/000
ARIT1
Function
OUT = IN1*IN2
C0339/001
ARIT1
IN1
MCTRL-IACT
C0339/002
ARIT1
IN2
MCTRL-IACT
C0685/000
CMP2
Comparison operation
|In1| > |IN2|
C0686/000
CMP2
Hysteresis
1%
C0687/000
CMP2
Window
1%
C0688/001
CMP2
IN1
PT1-1-OUT
C0688/002
CMP2
IN2
FCODE-472/1 (limit value)
C0871/000
DCTRL
TRIP-SET
OR1-OUT
C0830/001
OR1
IN1
CMP2-OUT
C0830/002
OR1
IN2
DIGIN4
C0830/003
OR1
IN3
Fixed 0
C0640/000
PT1-1
Time constant
30 s
C0641/000
PT1-1
IN
ARIT1-OUT
Entry in the processing list of the function blocks
Code
Function block
Name
Current
C0685/032
---
FB processing list
ARIT1
C0465/034
---
FB processing list
PT1-1
C0465/035
---
FB processing list
CMP2
C0465/036
---
FB processing list
OR1
The configuration 1000 or 1010 (speed control) forms the basis for this function block
interconnection.
Show/Hide Bookmarks