Implementation of function block interconnection

Code list
Code

Function block

Name

Current

C0338/000

ARIT1

Function

OUT = IN1*IN2

C0339/001

ARIT1

IN1

MCTRL-IACT

C0339/002

ARIT1

IN2

MCTRL-IACT

C0685/000

CMP2

Comparison operation

|In1| > |IN2|

C0686/000

CMP2

Hysteresis

1%

C0687/000

CMP2

Window

1%

C0688/001

CMP2

IN1

PT1-1-OUT

C0688/002

CMP2

IN2

FCODE-472/1 (limit value)

C0871/000

DCTRL

TRIP-SET

OR1-OUT

C0830/001

OR1

IN1

CMP2-OUT

C0830/002

OR1

IN2

DIGIN4

C0830/003

OR1

IN3

Fixed 0

C0640/000

PT1-1

Time constant

30 s

C0641/000

PT1-1

IN

ARIT1-OUT

Entry in the processing list of the function blocks
Code

Function block

Name

Current

C0685/032

---

FB processing list

ARIT1

C0465/034

---

FB processing list

PT1-1

C0465/035

---

FB processing list

CMP2

C0465/036

---

FB processing list

OR1

The configuration 1000 or 1010 (speed control) forms the basis for this function block

interconnection.