8 parameterisation 9300 series, Change and save parameters, Parameterisation 9300 series – Lenze EMZ9371BC User Manual

Page 106

Advertising
background image

8

Parameterisation 9300 series

Change and save parameters

EDK9371BC DE/EN/FR 3.1

106

l

Parametrierung 9300−9371BCme93

8

Parameterisation 9300 series

Change and save parameters

All parameters for controller setting or monitoring are saved in codes. The codes are
numbered and labelled in the documentation with a "C". Some codes store the parameters
in numbered subcodes", so that a clear parameter setting is ensured (e. g.: C0517 User
menu).

The codes are described in detail in the system manual of the drive controller.

)

Note!

Your settings have an effect on the current parameters in the main memory.
You must save your settings in a parameter set so that they are not lost when
the mains are connected.

If you only need one parameter set, save your settings as parameter set 1, since
parameter set 1 is loaded automatically after mains connection.

Step

Key sequence

Action

1.

Select the menu

z y Z Y

Use the arrow keys to select the desired
menu

2.

Change to the code level

Z

Display of the first code in the menu

3.

Select code or subcode

y z

Display of the current parameter value

4.

Change to the parameter level

V

5.

When SHPRG is displayed,
inhibit the controller

S

1)

The drive coasts

6.

Change parameter

A

Z Y

Move cursor below the digit to be
changed

B

y z

Change of digit

T y

T z

Quick change of digit

7.

Accept the changed parameter

Display of SHPRG or SHPRG

p T V

Confirm change to accept the parameter
Display "OK"

Display

p

The parameter has been accepted
immediately

8.

Enable the controller, if
required

U

1)

The drive runs again

Advertising