Restoring default (as delivered) settings – Lenze EMZ9371BC User Manual

Page 83

Advertising
background image

Parameterisation 8200 vector/8200 motec

Restoring default (as delivered) settings

7

EDK9371BC DE/EN/FR 3.1

83

l

H1 Parametrierung 8200−9371BC_6L

Restoring default (as delivered) settings

Step

Key sequence

Action

1.

Connect the keypad to the
standard device

2.

Inhibit the controller

S

The drive coasts

3.

Select the "Load/Store"
submenu 7.1 in the "Param
managm" menu 7

z y Z Y

Change to the "Load/Store" submenu
using the arrow keys

4.

Change to the code level

Z

"Param managm" is displayed in C0002

5.

Change to the parameter level

V

"0" and "READY" are displayed

6.

Select the correct copy function

The settings stored in the standard
device or in the function module are
overwritten.

l

Load parameter sets (PARx) into the standard device:

– Restore the delivery

status in the selected
parameter set of the
standard device

z

Load PAR1:

ð

Set "1" "Keypad−>PAR1"

Load PAR2:

ð

Set "2" "Keypad−>PAR2"

Load PAR3:

ð

Set "3" "Keypad−>PAR3"

Load PAR4:

ð

Set "4" "Keypad−>PAR4"

l

Load the parameter set (FPAR1) into the fieldbus function module:

– Restore the delivery

status in the fieldbus
function module

z

Load FPAR1

ð

Set "31" "Keypad−>FPAR1"

Advertising