Parameterisation 9300 series
Load parameter set
EDK9371BC DE/EN/FR 3.1
109
l
Parametrierung 9300−9371BCme93
Step
Key sequence
Action
1.
Inhibit controller
Terminal X5/28 = LOW
2.
Load the saved parameter set
into the main memory
A
z y Z Y
Select the code C0002 "PAR LOAD" in the
menu "Load/Store"
B
V
Change to the parameter level
The active parameter set is displayed,
e. g. display "0" and "Load Default"
If you want to restore the delivery status,
proceed with D
Select the parameter set
to be loaded
C
z
Load parameter set 1:
ð
Set "1" "Load PS1"
Load parameter set 2:
ð
Set "2" "Load PS2"
Load parameter set 3:
ð
Set "3" "Load PS3"
Load parameter set 4:
ð
Set "4" "Load PS4"
D
T V
"RDY" goes off. The parameter set is
loaded completely into the main memory
if "RDY" is displayed again.
3.
Change to the code level
A
V
Display of the operating level
B
V
Display of C0002 "PAR LOAD"
4.
Enable controller
Terminal X5/28 = HIGH
The drive is running with the settings of
the loaded parameter set