Parameterisation 9300 series – Lenze EMZ9371BC User Manual

Page 109

Advertising
background image

Parameterisation 9300 series

Load parameter set

8

EDK9371BC DE/EN/FR 3.1

109

l

Parametrierung 9300−9371BCme93

Step

Key sequence

Action

1.

Inhibit controller

Terminal X5/28 = LOW

2.

Load the saved parameter set
into the main memory

A

z y Z Y

Select the code C0002 "PAR LOAD" in the
menu "Load/Store"

B

V

Change to the parameter level
The active parameter set is displayed,
e. g. display "0" and "Load Default"
If you want to restore the delivery status,
proceed with D

Select the parameter set
to be loaded

C

z

Load parameter set 1:

ð

Set "1" "Load PS1"

Load parameter set 2:

ð

Set "2" "Load PS2"

Load parameter set 3:

ð

Set "3" "Load PS3"

Load parameter set 4:

ð

Set "4" "Load PS4"

D

T V

"RDY" goes off. The parameter set is
loaded completely into the main memory
if "RDY" is displayed again.

3.

Change to the code level

A

V

Display of the operating level

B

V

Display of C0002 "PAR LOAD"

4.

Enable controller

Terminal X5/28 = HIGH
The drive is running with the settings of
the loaded parameter set