The keypad serves to load a saved parameter set into the main memory when the controller
is inhibited. After the controller is enabled, it operates with the new parameters.

}

Danger!

ƒ

When a new parameter set is loaded, the controller is reinitialised and acts
as if it had been connected to the mains:
– System configurations and terminal assignments can be changed.

Make sure that your wiring and drive configuration comply with the
settings of the parameter set.

ƒ

Only use terminal X5/28 as source for the controller inhibit! Otherwise the
drive may start in an uncontrolled way when switching over to another
parameter set.

)

Note!

ƒ

After switching on the supply voltage, the controller always loads
parameter set 1 into the main memory.

ƒ

It is also possible to load other parameter sets into the main memory via
the digital inputs or bus commands.